Recall any program that has already been set up for a product type and
target weight similar to the new product and target weight.
Determine the difference between the existing (pre-programmed) target
weight and the new target weight.
Press command:
"A" to add value to the existing target weight,
or
"B" to subtract value from the existing target weight.
Press "E" to enter the difference from step #2 above to add or subtract
(always 4 digits --- use leading zeroes if necessary.
Store the new program, using command "E," if desired.*
EXAMPLE
Suppose program #02 has already been set up for 2.00 oz. of rice, and let's
say you have a new requirement for 1.75 oz. of dry beans:
You would recall program #02, press command "B" to subtract, then enter "0025" (the difference between 2.00 oz. and 1.75 oz.).
That's it! You're done. The controller makes the other adjustments,
automatically.
You can store* the changes by using command "E" followed by a 2-digit
memory location of your choice. Program #02 remains unaffected unless the new information is stored in #02.
*See "Quick Check Guide" for more complete listing of command and set-up procedures and "Supervisor Codes" (paragraph C) if override command is required.